Portable electrical power distribution system test measurement equipment moving iron moving coil pointer analog panel meter
I.Usage and application: Analog display electrical measuring ammeter voltmeter
This series of instruments directly simulates the display of electrical measurement indications, measure DC current, voltage, AC current, voltage, frequency, power factor, phase sequence, power, synchronization indication and other non-electricity measurements. It is widely used in various railways, DC transmission and distribution systems, power control panels and other electrical equipment for maritime ships, rail transit, chemical explosion-proof, low-voltage complete sets of equipment, construction equipment, generator sets, machinery and equipment industries. Acting on electrical measurement and non-electrical measurement, it is a general-purpose medium and high-grade instrument suitable for general requirements of environmental conditions.Portable electrical power distribution system test measurement equipment moving iron moving coil pointer analog panel meter
II.Standards and certifications: portable diesel generator use moving-iron moving-coil analog panel meter
The analog panel meter is in accordance with GB/T7676-1998, the digital display instrument is produced according to GB/T22264-2008 standard, and its safety performance is produced according to GB4793 and IEC61010 standards. The scale and pointer design of the dial conforms to the German DIN43790 and DIN43802 standards. The shape and opening size of the meter are produced in accordance with GB/T1242 and IEC61554 standards.
III.Analog panel meter shells: distribution system electricity single-phase led digital ammeter
The CT series base is made of flame retardant TBT plastic with a Vicat temperature of 130 °C. The outer casing is made of flame-retardant ABS plastic with a Vicat temperature of 85 °C.
IV.Temperature-induced change: panel mounted programmable alarm single-phase led digital voltmeter
The reference temperature is 23 °C ± 2 °C, 13 °C ~ 23 °C and 23 °C ~ 33 °C temperature range, the temperature change allowable change is not greater than ± 100% of the grade index.Portable electrical power distribution system test measurement equipment moving iron moving coil pointer analog panel meter
V.Installation location and installation method: LED three phase digital voltmeter ammeter combination
Unless otherwise specified, the meter is usually installed in a vertical position. Other installation locations such as: horizontal installation, tilt installation can be made according to customer requirements. The accuracy level of the response is only valid for the specified installation location. The meter is divided into a right angle of 90 ° and a wide angle of 250 °, two angles of indication.
VI.Resistance to vibration and shock: three phase digital voltmeter analog output 4-20ma
Anti-vibration: in accordance with IEC60068-2-6 standard; sweep frequency range: 10-55-10Hz; displacement amplitude: ±0.15mm, ±0.3mm. Sweep cycle number: 5 times; sweep rate: 10ct/min; maximum acceleration: 147m/s2 (15g), 490m/s2 (50g). Acceleration effective value: 6.06g; Vibration time: 15min. Anti-mechanical impact, in line with IEC60068-2-27 standard.Portable electrical power distribution system test measurement equipment moving iron moving coil pointer analog panel meter
VII.Accuracy level:
CT series pointer meter: AC and DC voltmeter and ammeter are 1.5 or 2.5, the power meter is 2.5, the frequency meter is 2.5, and the power factor meter is 2.5.
VIII.Overload current meter: three phase digital ammeter digital input output
The overload multiplier is conventionally 1x and 2x overload multiples, which can be customized to 1x, 2x, 3x, etc. by the user. Its role is to indicate the approximate value of the instantaneous overload current, such as the starting current when the motor starts.
IX.External current shunt:
The DC current meter has a shunt voltage drop specification of 150mV, 100mV, 75mV, 60mV and 50mV, which can be customized by users. The wire resistance of the meter and the shunt is required to be within 15~25mΩ to ensure the accuracy of the meter.Portable electrical power distribution system test measurement equipment moving iron moving coil pointer analog panel meter
X.Surface dial: low voltage switchgear use digital panel meter with RS485
Surface dial: Made of aluminum alloy, white paint, black ink or laser print. The dial can be customized according to the customer's sample (multiple color overprinting can be customized). The luminous table dial uses a PC board.Portable electrical power distribution system test measurement equipment moving iron moving coil pointer analog panel meter
XI.Zero regulator aspect: multifunction power meter with RS485
Except for the mechanical zero reading instrument, all other instruments have a front zero adjuster for adjusting the mechanical zero position of the instrument.
XII.The main technical parameters:CE approved panel mount programmable switchboard LCD digital power meter
Name | Code | Accuracy | Commonly used specifications | Remarks |
AC ammeter | A | 2.5 | 0.5-50A | Direct connection |
AC ammeter | A | 2.5 | 10/5A-800/5A | Passing secondary current through current transformer |
AC ammeter | KA | 2.5 | 1KA-10KA | Passing secondary current through current transformer |
AC voltmeter | V | 2.5 | 10V-600V | Direct connection |
AC voltmeter | KV | 2.5 | 1KV-35KV | Passed the voltage transformer, the secondary voltage is 100V |
DC ammeter | uA mA | 2.5 | 50uA-500uA 1mA-500mA | Direct connection |
DC ammeter | A | 2.5 | 1A-15A | Direct connection |
DC ammeter | A | 2.5 | 15A-750A | Connect with external shunt 75mV,60mV,50mV |
DC ammeter | KA | 2.5 | 1KA-3KA | Connect with external shunt 75mV,60mV,50mV |
DC voltmeter | V | 2.5 | 3V-600V | Direct connection |
DC voltmeter | KV | 2.5 | 1KV-3KV | External fixed resistance is attached |